HOME > UL8 Portable Fire Extinguisher

  • UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher
  • UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher
  • UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher
  • UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher
name: UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher
date: 2024-03-28 14:29:33
view: 127
about:

      Our company mainly sells fire extinguishers and door products, such as dry powder fire extinguisher, carbon dioxide fire extinguisher, foam fire extinguisher, automatic fire extinguisher, paint-free door.We are located in Jiangshan, Zhejiang...




DETAIL



UL Rust & Corrosion Proof Aluminum 20LB 9KGS Carbon Dioxide Fire Extinguisher

UL Extinguisher Product Details

Place of Origin:  Jianshan city, Zhejiang Province, China

Brand Name:   BOYO INTERIOR MATERIALS

Certificate:     UL/DOT

Model No.:     BY-9ULRCO2

UL Extinguisher Payment & Shipping Terms

Minimum Order Quantity:  UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher 100PCS

Price:  UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher According to The Final Quantity and Cost

Package: UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher 3 Corrugated Paper Boxes with Pallets for LCLFCL without Pallets

Delivery Time:  UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher 7-15 Days

Payment term: UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher L/C at Sight, T/T, D/P at Sight

Price Term: FOB SHANGHAI /NINGBO Port, CNF/CIF Destination Port

 

UL Rust & Corrosion Proof Aluminum 20LB 9KGS Carbon Dioxide Fire Extinguisher

UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher Description

Model No.: BY-9ULRCO2                 Filling Weight: 20LB (9KGS)

Working Pressure: 125BAR(1800psi)      Test Pressure: 210BAR3000psi

Type : Corrosion Proof CO2 Extinguisher  Materials: AA6061

UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher Special Features

1. Carbon dioxide is non-polluting because carbon dioxide is a gas and will diffuse into the air after the fire is extinguished and will not cause damage to the objects on fire.

2. Carbon dioxide fire extinguishing efficiency is slightly higher, suitable for fires in small spaces, and is easier to put out.

3. Light weight: The aluminum alloy fire extinguisher shell is made of high-strength aluminum alloy material, which is light in weight and easy to carry and operate.

4. Beautiful appearance: The aluminum alloy shell has a bright surface, gorgeous color, high surface finish, beautiful appearance, and is suitable for high-end public places.

5. Light weight, easy to use for the elderly, children and ladies.

6. Good durability: Aluminum alloy materials are corrosion-resistant and wear-resistant and have a long service life.

7. CO2 fire extinguisher is mainly suitable for fires involving various flammable and combustible liquids and combustible gases. It can also be used to extinguish initial fires in instruments, books and archives, craft equipment and low-voltage electrical equipment.

UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher Technology Data

ITEM

UNIT

SPECIFICATION

FILLING WEIGHT

LB

20

CAPACITY

L

13.6

CYLINDER HEIGHT

MM

600

CYLINDER DIAMETER

 

MM

202

 

CYLINDER WEIGHT

KGS

11

CAPACITY

KGS

4.5

FULL WEIGHT OF EXTINGUISHER

KGS

21.5

TEMPERATURE RANGE

bellow -30-50

WORKING PRESSURE

BAR

125(1800psi)

TEST PRESSURE

BAR

210(3000psi)

FIRE RATING

BAR

10B/C

MATERIALS

S

AA6061

 

UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher Precautions

1. Open-air fire extinguishers are not effective at extinguishing fires if it is wind weather.

2. Before spraying, remove the safety device and then press the handle.

3. Because the effective spray distance of carbon dioxide fire extinguishers is small, the distance from the fire source should not be too far when extinguishing the fire. Generally, about 2 meters is better.

4. Do not touch metal parts with your hands during spraying to prevent frostbite.

5. After spraying in a small confined space or underground tunnel, people should evacuate immediately to prevent suffocation.

6. When the fire extinguisher is stored, it is strictly prohibited to be near a heat source or exposed to the sun. Check it regularly and use a well-known person's weight to check whether there is leakage of carbon dioxide gas.


How to Use a UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher

UL 20LB 9KGS Rust Carbon Dioxide Fire Extinguisher(图1)

1. Place the handle of the CO2 fire extinguisher on the fire outlet, about two meters away from the fire source.

2. Put down the CO2 fire extinguisher and adjust the position of the horn. Since the carbon dioxide fire extinguisher does not have a black hose, the horn should be turned upwards 70 to 90 degrees.

3. Remove the CO2 fire extinguisher lead seal and safety bolt.

4. Hold the handle at the root of the horn with one hand, hold the pressure handle of the opening and closing valve tightly with the other hand, and shoot at the root of the upwind supply source.

5. When using, try to prevent skin from frostbite caused by direct contact with the spray barrel and spray hose. When putting out an electrical fire, if the voltage exceeds 600 volts, remember to cut off the power supply before putting out the fire.




在线客服