Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher

Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher   

Product Details

Place of Origin:  Jianshan city, Zhejiang Province, China

Brand Name:   BOYO INTERIOR MATERIALS

Certificate:    CE/ISO

Model No.:     BYD-8DCP

Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher Payment & Shipping Terms

Minimum Order Quantity:  Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher 100PCS

Price: Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher According to The Final Quantity and Cost

Package: Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher 3 Corrugated Paper Boxes with Pallets for LCLFCL without Pallets

Delivery Time:  Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher 7-15 Days

Payment term: Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher L/C at Sight, T/T, D/P at Sight

Price Term: FOB SHANGHAI /NINGBO Port, CNF/CIF Destination Port

 

Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher

Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher Description

Model No.: BYD-8DCP              Capacity: 6.5L

Materials: SPCC                    Test Pressure: 27BAR

Object: Class ABC                 Type: SPCC Portable ABC Dry Powder Extinguisher

Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher

Advantages

1. Convenient storage. Dry powder fire extinguishing agents are usually stored in dry powder fire extinguishers or dry powder fire extinguishing equipment.

2. It is easy to use. When extinguishing a fire, the dry powder is ejected from the nozzle by the pressure of pressurized gas carbon dioxide or nitrogen.

3. Fire extinguishing speed is fast.

4 .The cost of dry powder fire extinguishing agent is low.

Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher Technology Data

ITEM

UNIT

SPECIFICATION

CAPACITY

KGS

8

CAPACITY

L

10.5

CYLINDER HEIGHT

MM

490

CYLINDER DIAMETER

MM

165

FULL WEIGHT OF EXTINGUISHER

KGS

9.5

TEMPERATURE RANGE

bellow -20-55

WORKING PRESSURE

BAR

14

TEST PRESSURE

BAR

27

FIRE RATING

BAR

34A/183B/C

MIN. DISCHARGE TIME

S

14

MIN. DISCHARGE DISTANCE

 M 

 4.5 


How to Use a Recharge 8KGS ABC Portable Dry Chemical ABC Extinguisher

8kgs ISO and CE Standards ABC Portable Dry Powder Extinguisher(图1)

The First Step: Pulling The Extinguisher Safety Pin

Keep the cylinder upright and pull the safety pin. The safety pin ensures that the content remains pressurized; once it is taken out, you will be able to activate the extinguisher and use it to stop the fire.

The Second Step: Aiming The Extinguisher Nozzle Against The Fire SourceOnce the safety pin is out, aim the nozzle against the source of the flames.

The Third Step: Squeezing The Extinguisher Handle

You will need to squeeze the handle, to push the content out for it to do its job.

The Forth Step: Sweeping Over The Source Of The Flames

To make sure that the fire is completely put out, you need to use a sweeping. motion over the source of the flames.

 

What is Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher?

The fire extinguishing agents of dry powder fire extinguishers are mainly ammonium phosphate and sodium bicarbonate (BC type sodium bicarbonate) fire extinguishing agents. The driving gas is nitrogen, and its working pressure is 1.5MPa at normal temperature. The cylinder body is made of high-quality carbon steel processed by special technology. Fire extinguishers are mainly composed of cylinders, bottle valves, spray hoses (nozzles), etc.

What is Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher scope of use?

1. Class A ordinary fire: any fire caused by solid materials such as wood, paper, cotton, cloth, plastic, etc..

2. Class B oil fire: any fire caused by flammable liquids and solid grease objects, such as gasoline, petroleum, kerosene, etc..

3. Class C gas fire: Any fire caused by gas combustion or explosion is called gas fire, such as natural gas, coal gas, etc..

 

What is Recharge 8KGS ABC Portable Dry Chemical Powder Extinguisher of precautions?

1. When using a portable dry powder fire extinguisher, the safety pin must be pulled out first, otherwise the dry powder will not spray out.

2. The spray time and distance of the portable dry powder fire extinguisher are very short, so before use, you must aim the powder spray hose at the flame before opening the valve.

3. Before using the portable dry powder fire extinguisher, turn the cylinder up and down several times to loosen the dry powder and the spray effect will be better.

4. The spray of dry powder fire extinguisher does not have a concentrated jet, and it is easy to spread out after spraying. Therefore, when spraying, the operator should stand upwind of the fire source.

5. Dry powder fire extinguishers should not spray towards the flame from above, but should shoot flatly at the root of the flame, from near to far, push forward and sweep left and right to prevent the flame from jumping back.

6. Dry powder fire extinguishers can be effective for 3-5 years under normal circumstances, but they should be inspected once a year.

7. Dry powder fire extinguishers should be placed in a convenient, ventilated, cool and dry place to prevent the cylinder from getting damp and the dry powder from clumping. Dry powder fire extinguishers should not be exposed to high temperatures, nor should they be placed in places with temperatures below -10 degrees Celsius.